CyberPower CP1500PFCLCD vs APC BR1500MS2: Which 1500VA UPS?
Quick answer: Choose the CyberPower CP1500PFCLCD if the extra 100W of rated output and a 12-outlet layout solve your actual load problem. Choose the APC BR1500MS2 if you prefer its Back-UPS Pro ecosystem, its documented APCRBC163 replacement battery, and a six-battery-outlet layout in a 10-outlet chassis. Both are line-interactive, sine-wave UPS units; neither is automatically the right choice without checking your connected load and shutdown software.
These two models are often compared because the headline 1500VA rating and sine-wave output look equivalent. They are not identical in usable watt headroom or outlet allocation. For a NAS plus router the difference may be minor; for a workstation plus networking gear it may matter.
Check the exact models: CP1500PFCLCD on Amazon | BR1500MS2 on Amazon. Prices, stock and sellers can change; confirm the model number before ordering.
Affiliate disclosure: As an Amazon Associate, UPSIndex may earn from qualifying purchases.
At a glance: exact-model specifications
| Specification | CP1500PFCLCD | BR1500MS2 |
|---|---|---|
| Rated capacity | 1500VA / 1000W | 1500VA / 900W |
| Topology | Line Interactive | Line Interactive |
| Battery output waveform | Sine Wave | Sine Wave |
| Total AC outlets | 12 | 10 |
| Battery-backed outlets | 6 | 6 |
| Surge-only outlets | 6 | 4 |
| Form factor | Mini-Tower | Tower |
Capacity and outlet counts are manufacturer-model specifications, not promises of runtime or live retailer availability.
For the full database entries, see CP1500PFCLCD and BR1500MS2. You can also compare both UPS models side by side using the UPSIndex comparison tool.
The extra 100W is real, but it is not extra battery time
CyberPower rates the CP1500PFCLCD at 1500VA/1000W; APC rates the BR1500MS2 at 1500VA/900W. A UPS must remain within both its VA and watt limits. A 700W measured load leaves 300W of rated watt margin on the CyberPower and 200W on the APC, before allowing for power spikes or future equipment.
Do not interpret that 100W difference as longer runtime. Runtime depends on battery energy, conversion losses and the load at which it is measured. Compare each manufacturer’s runtime curve at your own watts, rather than comparing a half-load number from one product with a full-load number from the other.
Count battery-backed outlets, not just total sockets
The CP1500PFCLCD has 12 AC outlets, split into six battery-backed/surge-protected and six surge-only. The BR1500MS2 has 10, split into six battery-backed and four surge-only. In other words, both provide six outlets that can keep devices running when the power fails.
This matters when you are protecting a NAS, switch, router, modem and desktop at the same time. Connect only the devices that truly need backup to the battery side; speakers, printers and chargers can use surge-only outlets where appropriate. Check physical spacing for bulky adapters as well as the outlet count.
Both use sine-wave battery output and automatic voltage regulation
These are not a simulated-sine-versus-sine comparison. Both manufacturers describe the products as sine-wave line-interactive UPS systems with automatic voltage regulation (AVR). AVR can correct certain input-voltage fluctuations without consuming battery charge.
For a PC with an active-PFC power supply, sine-wave output is a sensible way to reduce waveform-related uncertainty. It does not guarantee every PSU/UPS pairing will behave identically, and it does not replace proper sizing for startup surges or sustained power draw.
NAS shutdown: test the exact software path
A UPS protecting storage should notify the NAS or host when power fails and allow a clean shutdown. Both models have USB communication options, but compatibility is determined by the NAS operating system, UPS firmware, cable and supported protocol. Do not assume a USB-A charging port is the same thing as a UPS data port.
If your storage is a four-bay system such as the Synology DS925+ reviewed on DiskBarn, keep the NAS and the network devices required for alerts on battery power. Confirm the exact UPS in your NAS vendor’s compatibility information, or perform a controlled outage test after setup. A short, predictable shutdown is more useful than an untested promise of a long runtime.
Replacement batteries and the long-term cost
APC identifies a user-replaceable battery for the BR1500MS2; the UPSIndex record lists APCRBC163. CyberPower also describes the CP1500PFCLCD as having a user-replaceable battery, but verify the cartridge SKU against the serial number and current manufacturer documentation before ordering.
A lower checkout price is not automatically the lower ownership cost. Factor in replacement cartridges, warranty terms, how accessible the battery is, and whether the UPS will be in a location where swapping a heavy battery is practical. Retail availability varies by seller and date; neither listing should be treated as guaranteed in stock.
Which should you buy?
Choose CP1500PFCLCD when your measured load benefits from the 1000W ceiling, you need more surge-only sockets, or you want the CyberPower PowerPanel ecosystem. Choose BR1500MS2 when the 900W limit comfortably covers your setup, six battery-backed sockets are sufficient, and the APC battery and software path is a better operational fit.
For either choice, make a list of the devices that must remain powered, measure watts under normal and peak conditions, then compare runtime at that load. The right purchase is the one that supports a clean, repeatable shutdown—not the one with the larger number of total sockets.
Common buying questions
Does 1500VA mean the same runtime?
No. VA is an output-capacity rating. Runtime is determined by the load and the battery/runtime curve for each specific UPS.
Which has more battery-backed outlets?
Neither: both provide six battery-backed AC outlets. CyberPower has two more surge-only outlets.
Are these both suitable for a NAS?
They are reasonable candidates, but confirm USB shutdown compatibility with the exact NAS model and operating system before relying on automation.
Bottom line
For a mixed desktop-and-network load close to 900W, the CP1500PFCLCD offers useful rated watt headroom. For lighter loads, the BR1500MS2 remains a credible sine-wave alternative with a well-defined APC service path. Compare current exact-model offers and your runtime requirements rather than choosing by VA alone.
Manufacturer references and verification
Technical ratings and model-specific features were checked against the CP1500PFCLCD manufacturer page and the BR1500MS2 manufacturer page. UPSIndex uses exact-model specifications; retailer stock, revisions, battery cartridge compatibility and runtimes should be rechecked before purchase. Research reviewed October 8, 2026.